Accessories
Our accessory solutions offer more options for everyday installation use. The portfolio includes brackets for custom-fit speaker mounting, power supplies, charging stations and signal splitters, as well as essential helpers and problem solvers for both small and large AV projects.
Sort by:
AUDAC
TRM024
The TRM series are 70/100V line transformers that can be optionally implemented in the passive variants of the VEXO series. Installation is done by removing the backplate of the VEXO series (passive variants only) and replacing it with a 70/100V backplate on which the module is integrated. Like this, the high-performance loudspeaker can be implemented in 70/100V systems.
Color:
Black
Color
AUDAC
TRM012
The TRM series are 70/100V line transformers that can be optionally implemented in the passive variants of the VEXO series. Installation is done by removing the backplate of the VEXO series (passive variants only) and replacing it with a 70/100V backplate on which the module is integrated. Like this, the high-performance loudspeaker can be implemented in 70/100V systems.
Color:
Black
Color
AUDAC
TRM248
The TRM series are 70/100V line transformers that can be optionally implemented in the passive variants of the VEXO series. Installation is done by removing the backplate of the VEXO series (passive variants only) and replacing it with a 70/100V backplate on which the module is integrated. Like this the high-performance loudspeaker is able to be implemented in 70/100V systems.
Color:
Black
Color
AUDAC
TRM124
The TRM series are 70/100V line transformers that can be optionally implemented in the passive variants of the VEXO series. Installation is done by removing the backplate of the VEXO series (passive variants only) and replacing it with a 70/100V backplate on which the module is integrated. Like this the high-performance loudspeaker is able to be implemented in 70/100V systems.
Color:
Black
Color
AUDAC
TRM224
The TRM series are 70/100V line transformers that can be optionally implemented in the passive variants of the VEXO series. Installation is done by removing the backplate of the VEXO series (passive variants only) and replacing it with a 70/100V backplate on which the module is integrated. Like this the high-performance loudspeaker is able to be implemented in 70/100V systems.
Color:
Black
Color
AUDAC
TR2070
The TR2070 is a basic ground loop isolator designed to electrically isolate audio devices from each other. Hum in audio systems is usually caused by ground loops in the system. A common mode current will flow in a ground loop created by an electrical system that has grounds on different voltage potentials. This results in a 50 Hz hum in the audio signal. The most common method to solve these problems is an audio isolation transformer such as the TR2070 which always need to be in reach for every audio technician. When ground loop problems are encountered, these can be solved in a jiffy, by using the TR2070.
TR2070 has a 3.5 mm jack male and jack female.
AUDAC
TR1006F
The TR1000 series are 100 Volt line transformers designed for impedance matching between loudspeakers and amplifiers. They are used for converting low impedance speakers allowing them to be used in 100V PA installations where long cableruns can be used. The transformers have an over-dimensioned core, which limits saturation to a minimum and gives remarkable improvement of the sound reproduction quality especially in the low frequencies. There are several power taps available for 100V and depending of the transformer that is used, the output impedance can also be selected.
TR1006F has a maximum output power of 6 Watt and different power taps for 6 Watt, 3 Watt and 1.5 Watt.
AUDAC
TR2080
The TR2070 is a basic ground loop isolator, designed to electrically isolate audio devices from each other. Hum in audio systems is usually caused by ground loops in the system. A common mode current will flow in a ground loop created by an electrical system that has grounds on different voltage potentials. This results in a 50 Hz hum in the audio signal. The most common method to solve these problems is an audio isolation transformer such as the TR2080 which always need to be in reach for every audio technician. When ground loop problems are encountered, these can be solved in a jiffy, by using the TR2080.
TR2080 has a 3.5 mm jack and two XLR male connectors.
AUDAC
TR2060
The TR2060 is a basic ground loop isolator, designed to electrically isolate audio devices from each other. Hum in audio systems is usually caused by ground loops in the system. A common mode current will flow in a ground loop created by an electrical system that has grounds on different voltage potentials. This results in a 50 Hz hum in the audio signal. The most common method to solve these problems is an audio isolation transformer such as the TR2060 which always need to be in reach for every audio technician. When ground loop problems are encountered, these can be solved in a jiffy, by using the TR2060.
TR2060 has a 3.5 mm jack and two RCA male connectors.
AUDAC
TR1024F
The TR1000 series are 100 Volt line transformers designed for impedance matching between loudspeakers and amplifiers. They are used for converting low impedance speakers allowing them to be used in 100V PA installations where long cableruns can be used. The transformers have an over-dimensioned core, which limits saturation to a minimum and gives remarkable improvement of the sound reproduction quality especially in the low frequencies. There are several power taps available for 100V and depending of the transformer that is used, the output impedance can also be selected.
TR1024F has a maximum output power of 24 Watt and different power taps for 24 Watt, 12 Watt and 6 Watt.
AUDAC
TR106
The AUDAC TR106 is a shielded true isolation audio transformer. Hum in audio systems is usually caused by ground loops in the system. A common mode current will flow in a ground loop created by an electrical system that has grounds on different voltage potentials. This results in a 50 Hz hum in the audio signal. The most common method to solve these problems is an audio transformer. The AUDAC TR106 audio isolation transformer with an in- and output impedance of 600 Ohm and a turns ratio of 1 : 1 has a very wide bandwidth and very low distortion which ensures a non distorted bass response and non attenuated high frequencies.
AUDAC
TR2050
The TR2050 is a basic ground loop isolator designed to electrically isolate audio devices from each other. Hum in audio systems is usually caused by ground loops in the system. A common mode current will flow in a ground loop created by an electrical system that has grounds on different voltage potentials. This results in a 50 Hz hum in the audio signal. The most common method to solve these problems is an audio isolation transformer such as the TR2050 which always need to be in reach for every audio technician. When ground loop problems are encountered, these can be solved in a jiffy, by using the TR2050.
TR2060 has two RCA Male and two RCA female connectors.
AUDAC
WTR24
The WTR24 is a 100 Volt line transformers for impedance matching between low impedance loudspeakers (8 Ohm) and 100 Volt amplifiers. Using the WTR24 line transformer, low impedance loudspeakers can be applied to any 100 Volt public address system where long cable runs can be used. The WTR24 has a maximum output power of 24 Watt and different power taps for 24 Watt, 12 Watt and 6 Watt. The housing is designed to be water- and dustproof, while making it possible to be hidden at any location such as above false ceilings, in wall junction boxes, in hollow places inside walls, ... The primary connection (100V side) is performed using a special designed waterproof AWX5 connector whereby the desired power tap can be selected depending on the rotation of the connector. The secondary connection (8 Ohm side) is performed using a waterproof cable gland. A connection cable with a length of 0.5 meter is provided on both sides of the transformer. The over-dimensioned core of the transformer limits the saturation to a minimum and gives a remarkable improvement of the sound reproduction, especially in the low frequency range. All these features make these transformers comply to an Ingress Protection rating of IP66.
AUDAC
WTR06
The WTR06 is a 100 Volt line transformers for impedance matching between low impedance loudspeakers (8 Ohm) and 100 Volt amplifiers. Using the WTR06 line transformer, low impedance loudspeakers can be applied to any 100 Volt public address system where long cable runs can be used. The WTR06 has a maximum output power of 6 Watt and different power taps for 6 Watt, 3 Watt and 1.5 Watt. The housing is designed to be water- and dustproof, while making it possible to be hidden at any location such as above false ceilings, in wall junction boxes, in hollow places inside walls, ... The primary connection (100V side) is performed using a special designed waterproof AWX5 connector whereby the desired power tap can be selected depending on the rotation of the connector. The secondary connection (8 Ohm side) is performed using a waterproof cable gland. A connection cable with a length of 0.5 meter is provided on both sides of the transformer. The over-dimensioned core of the transformer limits the saturation to a minimum and gives a remarkable improvement of the sound reproduction, especially in the low frequency range. All these features make these transformers comply to an Ingress Protection rating of IP66.
AUDAC
Q4TR/D
The Q4TR is a line transformer unit, especially designed to be used in combination with the Q4 quad channel power amplifier. It transforms the 4 Ohm low impedance loudspeaker outputs of the Q4 amplifier into loudspeaker signals to be used in constant voltage audio distribution systems, such as 100V, 70V or 50V systems. It features 4 separate audio line transformers with a total power of 4 x 600 Watt, and the transformers have power taps for 100V, 70V and 50V applications.